Hi Done a reasonable search though few hits regarding a Coke vending machine that has a faulty compressor, basically realcold the fan wiring connector arc through insulation & burnt a hole through the side of compressor adjacent klixon. Obviously lost it's charge & comp needs to be changed. Ok here in Syd Aust. told that Carrier have replacement comps for these 115Volt units though when I contacted them were puzzled! The comp is a Matsush it a Elec. model No. QA125V29CAU6, 115V. Can anyone shed some light with a replacement? If not 115volt change to 240volt using a relay perhaps? realcold Should I look at a reco? All advice appreciated. Last edited by Brian_UK; 30-03-2013 at 11:01 PM .
get the details of the matsu sh it a compressor - displacement, gas,high /med/low back pressures, capillary or exp valve, realcold starting method, psc or csr- dimensions, pipe positions, then you can compare with others for a suitable alternative compressor- danfoss ,kirby/tecumseh are reliable
29-03-2013, 11:19 PM #5
Thanks IM reckon that could be the original runs on R12 an oldie. Probably go with the slightly higher capacity one. The unit does have a step down tranny realcold from 240v-115v so could easily install a relay & run the 240v model. Thanks again very helpfull
This forum and its pages must not be copied or reprinted without the written consent of Refrigeration realcold Engineer.com. This forum is a free and open discussion board . Refrigeration-Engineer.com, the administrators and Moderators of this site are not responsible for content realcold posted here.
No comments:
Post a Comment